Stepper motors with Motion controllerOur stepper motors with integrated electronics use stepless control technology for 65,536 microsteps per revolution and offer encoder options such as magnetic incremental, single-turn absolute, or multi-turn absolute, to meet a wide range of applications. Communication options include CANopen, Modbus RTU, EtherCAT, Modbus TCP/IP, Profinet, PowerLink, IO-Link and Ethernet-IP, so the motors can be easily connected to any industrial network. Several of our models are IP65 rated, so they can be used in a wide range of environments where moisture or water spray is present.![]() More about Stepper motors with Motion controller |
![]() |
.

More Filters


Products
Product finder
Technology: |
Category: |
ISS42
Stepper with Motion controller
Size (mm) | 42 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 0,22 - 0,8 |
Current/Phase (A) | 2 |
Operating Voltage (Vdc) | 12 - 36 |
ISI42 -IP65
Stepper with Motion controller
Size (mm) | 42 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 0,22 - 0,8 |
Current/Phase (A) | 2 |
Operating Voltage (Vdc) | 12 - 36 |
ISS57
Stepper with Motion controller
Size (mm) | 57 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 0,55 - 1,89 |
Current/Phase (A) | 3 |
Operating Voltage (Vdc) | 12 - 48 |
ISI57 -IP65
Stepper with Motion controller
Size (mm) | 57 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 0,55 - 1,89 |
Current/Phase (A) | 3 |
Operating Voltage (Vdc) | 12 - 48 |
ISS60
Stepper with Motion controller
Size (mm) | 60 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 1 - 3,1 |
Current/Phase (A) | 3 |
Operating Voltage (Vdc) | 12 - 48 |
ISI60 -IP65
Stepper with Motion controller
Size (mm) | 60 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 1 - 3,1 |
Current/Phase (A) | 3 |
Operating Voltage (Vdc) | 12 - 48 |
ISS86
Stepper with Motion controller
Size (mm) | 86 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 3,4 - 12 |
Current/Phase (A) | 3 - 6,2 |
Operating Voltage (Vdc) | 12 - 48 |
ISI86 -IP65
Stepper with Motion controller
Size (mm) | 86 |
Interface | Modbus-RTU, CANopen, Modbus-TCP, EtherCAT. Profinet, PowerLink, IOLink, EtherNetIP |
Holding Torque (Nm) | 3,4 - 12 |
Current/Phase (A) | 3 - 6,2 |
Operating Voltage (Vdc) | 12 - 48 |